Desktop|中文
Home About Us
Products +
Company News Industry Trends Messages Contact Us

Product Details

全自动Dielectric Loss Tester-扬州达瑞

HXL-680 Tube-Fin Heat Exchanger

Published: 2026-10-18

产品价格:0.00

Views: 2922

Category: 管翅式换热器

Product Description

In flue gas ducts with high dust concentrations or hot air circulation systems, ash accumulation on heat exchanger fins gradually weakens heat transfer capability, and O&M personnel often need to balance cleaning methods, maintenance cycles, and equipment service life. The HXL-680 tube-fin heat exchanger provides a customizable ash accumulation control solution for such operating conditions.

Comparison of the Impact of Cleaning Methods on O&M

Mechanical rapping cleaning is relatively suitable for dry dust conditions, but long-term use may cause fatigue at the fin root, especially at the welded joint between the fin and the base tube. Online compressed air blowing has little impact on the production process and can be used as a routine maintenance measure; it is recommended to set the blowing cycle based on the on-site dust characteristics. For high-temperature dust-laden conditions, the fin pitch can be designed at 8~12 mm to reduce ash bridging; the base tube can use heat-resistant alloy steel, with a design task temperature of up to 850°C, meeting the hot air circulation requirements of heater supporting systems.

Structural Parameters and Customization Range

The design pressure, design temperature, and connection specifications of the HXL-680 tube-fin heat exchanger can be customized according to project requirements and should be clearly marked on the nameplate. The finned tube arrangement, fin pitch, and base tube material can be adjusted according to flue gas composition, dust concentration, and allowable pressure drop. The heat transfer area is determined through verification based on heat load and temperature difference, with no preset fixed value.

Installation and Maintenance Precautions

When the equipment is positioned, the fins should be protected from extrusion deformation, and the connection direction should be consistent with the pipeline routing. In the initial operation period, it is recommended to check ash accumulation once a week and adjust the blowing frequency according to pressure difference changes. During shutdown maintenance, the inspection door should be opened only after the equipment temperature has dropped to near ambient temperature, to avoid uneven contraction at the connection between the fins and the tube sheet caused by rapid cooling. If a mechanical rapping device is used, the rapping frequency and amplitude need to be checked regularly to prevent fatigue cracking at the fin root.

Applicable Conditions and Selection Recommendations

This type of heat exchanger is suitable for scenarios such as dust-laden flue gas waste heat recovery, hot air circulation heating, and drying systems. During selection, parameters such as flue gas flow rate, inlet and outlet temperatures, dust concentration, and allowable pressure drop need to be provided to determine the fin pitch and cleaning method. For high-dust conditions, priority should be given to online compressed air blowing combined with an adjustable fin pitch design; for dry dust and occasions where frequent shutdowns are not allowed in production, a combined mechanical rapping and blowing scheme can be evaluated.

WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us