全自动Dielectric Loss Tester-扬州达瑞

GCH-190 Shell-and-Tube Heat Exchanger

Published: 2026-10-22

产品价格:0.00

Views: 2922

Category: 管壳式交换器

Product Description

According to the design boundaries specified in GB/T 151, the GCH-190 shell-and-tube heat exchanger has a design pressure of 1.6 MPa and a design temperature range of -20°C to 150°C. The design pressure and design temperature shall be used separately for strength calculation and material allowable stress verification: the former determines the wall thickness of the shell, channel, and flanges, while the latter is used to verify the allowable stress and thermal expansion of each component at that temperature. The two parameters are not interchangeable and shall both be submitted to the manufacturer for verification during model selection.

Determination Path of Structural Parameters

The tube bundle length and baffle spacing are usually not directly specified by experience but are back-calculated from the allowable pressure drops of the shell side and tube side. When the pressure drop budget is ample, the tube bundle may be appropriately lengthened and the baffle spacing enlarged to reduce the cost per unit area; when the pressure drop is limited, the tube bundle is shortened and the baffle spacing reduced to obtain a higher heat transfer coefficient. The back-calculated structural parameters must also be substituted back to verify flow velocity and vibration, and finalized after confirming no abnormalities.

Correspondence Between Materials and Temperature Boundaries

The materials of the shell and tube bundle are selected according to the corrosiveness of the medium, and must simultaneously meet the allowable stress requirements within the range of -20°C to 150°C. At the low-temperature end, material toughness is of concern; at the high-temperature end, allowable stress reduction and expansion differential are of concern. When the temperature difference between the tube side and shell side is large, an expansion joint or a configuration other than a fixed tubesheet should be structurally provided, as determined by the calculated temperature difference.

Input Conditions to Be Submitted for Model Selection

When submitting parameters for design and model selection, it is recommended to include the names, flow rates, inlet and outlet temperatures, allowable pressure drops, corrosiveness descriptions, and installation space constraints of the media on both sides. Only when the above conditions are complete can the heat transfer area calculation and structural parameter back-calculation be completed. In the absence of allowable pressure drop data, the structural scheme often requires multiple rounds of adjustment.

WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us