How to match the power and explosion-proof rating of an electric heating furnace in metallurgical or chemical production lines?

The SLK-45 industrial electric heating furnace is mainly used for material heating and heat treatment in the fields of metallurgy, chemicals, ceramics, and semiconductors. The following key points are listed from the perspective of design and selection for reference by engineering and technical personnel.

Heating power and voltage level

This model has a rated power of 45kW, an input voltage of 380V three-phase AC, and the heating elements use a resistance wire structure, which can be switched in groups according to process temperature requirements. During design and selection, a comprehensive calculation must be made based on the material heat absorption power, furnace body heat dissipation, and heating rate, with a power margin of 10%~15% reserved.

Furnace chamber dimensions and loading method

The effective furnace chamber dimensions are 600mm×400mm×350mm (length×width×height), supporting trolley-type or box-type loading. For different workpiece shapes, the rack height and spacing can be adjusted to ensure uniform hot air circulation. During selection, the maximum loading weight and workpiece material should be clearly defined to avoid overload affecting temperature control accuracy.

Explosion-proof structure selection

If used in Class IIC gas environments such as hydrogen and acetylene, the furnace body explosion-proof rating must reach Ex d IIC T6 Gb, achieved by a flameproof enclosure and terminal chamber structure. During design and selection, a distinction must be made between the explosion-proof markings of electric heating furnaces and organic heat carrier furnaces; the former is determined by the furnace body structure, while the latter focuses on the explosion-proof treatment of the heat transfer oil circulation system.

Temperature control method and temperature range

The commonly used temperature control range of this equipment is room temperature to 650°C, using PID intelligent regulation and K-type thermocouple feedback, with temperature control accuracy up to ±3°C. For processes with higher temperature uniformity requirements, multi-zone heating and circulation fans can be optionally equipped. During selection, the upper limit of working temperature and whether a programmed heating curve is needed must be confirmed.

Typical application scenarios

The SLK-45 model is suitable for processes such as quenching of small metal parts, drying of chemical raw materials, binder removal from ceramic green bodies, and pre-packaging baking in semiconductor packaging. In laboratories, it can also be used as a heat source equipment for material sintering or heat treatment.

WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us