全自动Dielectric Loss Tester-扬州达瑞

SRY2/SRY4 Ordinary Tubular Electric Heater - Yangzhou Darui Co., Ltd.

Published: 2020-06-10 10:17:25

Views: 2922

Category: Sheath Heater

Product Description

SRY2/SRY4 Ordinary Tubular Electric Heater

SRY2/SRY4 Ordinary Tubular Electric Heater features compact size and high power: the heater mainly uses bundled tubular heating elements inside, with each bundled tubular electric heating element having a maximum power of 5000W.





Detailed Introduction





Material:



The outer tube is generally made of materials such as In800, In840, 304, 316L, 310S, aluminum, copper, low-carbon steel, etc.

Magnesium oxide powder is selected in different specifications according to different usage requirements, including high-temperature powder, medium-temperature powder, etc.

The resistance wire serves as the heating element, and there are generally two types of materials: Ni-Cr wire and Fe-Cr-Al wire.

The lead terminal materials generally include two types: stainless steel and free-cutting iron.



Technical Data:



Usage, Maintenance, and Precautions:



1. Dimension "B" in the outline drawing must be fully immersed in oil to avoid burning out the components. The heated oil should be non-corrosive.



2. When melting solid oils such as asphalt and paraffin, the voltage should be reduced for use, and then raised to the rated voltage after melting, to prevent heat concentration from reducing the service life of the components.



3. If carbon deposits are found on the tube surface, they must be removed before use to avoid reducing efficiency or even burning out the components.



4. Components should be stored in a dry place. If the insulation resistance drops below 1 megohm due to long-term storage, it can be restored by drying in an oven at about 200°C for several hours (or by applying low voltage to the components for several hours).



Dear Users:



Thank you for your interest in our products. In addition to this product introduction, our company also offers transformer electrical parameter testers, transformer capacity testers, withstand voltage testers, zinc oxide arrester testers, etc. If you are interested in our products, please consult us. Thank you!



SRY2/SRY4 Ordinary Tubular Electric Heater       SRY2/SRY4 Ordinary Tubular Electric Heater



1. Specifications and outline dimensions: see table and Figure 2

Note: The mounting hole for SRY2 and SRY4 types is Ø72 mm.

2. Working voltage allowable error: not greater than 1.1 times the rated value, and the shell should be effectively grounded.

3. Working environment: relative humidity not greater than 95%, no explosive or corrosive gases.

4. Metal tube material: No. 10 steel.

5. Maximum working temperature: SRY2 and SRY3 are 300°C, SRY4 is 100°C.

6. Working pressure for SRY2 and SRY4 types: less than 2 kg/cm².

7. Fastener length for SRY3 type: 25 mm.





Technical Parameters:





3. Working environment: relative humidity not greater than 95%, no explosive, flammable, or corrosive gases. 2. Working voltage allowable error: not greater than 1.1 times the rated value. The shell should be effectively grounded.



4. Metal tube material: No. 10 steel.



5. Working temperature: 100°C.



6. Working pressure for SRY2 and SRY4 types: less than 0.6MPa.



7. Oil tank opening: ≥φ65.




 

 




WeChat QR Code
💬
💬 Message

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us